PSA: quit zip tying cables to the drop ceiling wire, my old way vs now
Back when I started in Columbus about 6 years ago, I zip tied every run straight to the ceiling support wire because it was quick and looked tidy. Last week a maintenance guy cut one of those wires to get at a leak and took out 4 lines with it, and I spent 2 hours re-running drops. Now I use J-hooks spaced every 4 or 5 feet and a velcro wrap, costs a little more but nobody can slice my runs by accident. The zip tie method saved me maybe 10 minutes per job and cost me a whole afternoon at that site. Any of you keep a stash of J-hooks on the truck, or do you grab whatever the shop has that week?